16 POINT LEVEL DETECTION for liquids BASIC PRO BASIC VEGASWING 51/53 VEGASWING 61/63 VEGAPOINT 11 Sensor Vibrating level switch Vibrating level switch Capacitive level switch Application Liquids Liquids Water-based liquids Version VEGASWING 51: Compact version VEGASWING 53: Tube extension up to 1 m VEGASWING 61: Compact version VEGASWING 63: Tube extension up to 6 m Compact version of 316L, PEEK Measuring range – – – Material 316L 316L, ECTFE, PFA, enamel, Alloy 400, Duplex, Alloy C22 – Process fitting Thread from G½, ½ NPT, hygienic fittings Thread from G¾, ¾ NPT, flanges from DN 25, 1", hygienic fittings Threads from G½, ½ NPT, universal connector for hygiene adapter Process temperature -40 … +150 °C -50 … +250 °C -20 °C ... +100 °C/ 1 h @ +135 °C Process pressure -1 … +64 bar (-100 … +6400 kPa) -1 … +64 bar (-100 … +6400 kPa) -1 ... +25 bar (-100 ... +2500 kPa) Signal output Transistor output, contactless electronic switch, IO-Link Relay, transistor, two-wire, NAMUR output, contactless electronic switch Three-wire: PNP/NPN, IO-Link Display Control lamp (LED) Control lamp (LED) or pluggable display module PLICSLED LED Approvals VEGASWING 51: Overfill protection, Ship, CSA-OL, EHEDG, FDA, CE 1935/2004, EAC (GOST) VEGASWING 53: Overfill protection, CSA-OL, EHEDG, FDA, CE 1935/2004 ATEX, UKEX, IECEx, FM, CSA, EAC (GOST), UKR Sepro, Overfill protection, Ship, SIL2, KOSHA, NEPSI, INMETRO CE 1935/2004, FDA, ADI Benefit Minimal time and cost expenditure thanks to simple setup without medium Adjustment-free for easy setup Not all features and communication protocols are available at time of print. For the current and future releases contact VEGA Australia on 1800 817 135 | info.au@vega.com