12 PHOENIX CONTACT Buffer times for your QUINT AC UPS/1KVA with the following energy storage devices: LI-ION and VRLA-WTR Select your energy storage device for your QUINT AC UPS/1KVA (120 / 230 V application) here. Example: 400 W is to be buffered for three hours. Buffer times for your QUINT AC UPS/1KVA with the following PB energy storage devices: Select your energy storage device for your QUINT AC UPS/1KVA (120 / 230 V application) here. Example: 400 W needs to be buffered for 50 minutes: Uninterruptible Power Supplies (UPS) AC Power - 1 kVA Capacity - ONLINE UPS Note: Can be connected in parallel for 2kVA Capacity. (See manual for details) For use with AC QUINT power supply Select UPS UPS Module What input voltage? What output power/current? QUINT UPS QUINT IQ Technology State of Charge: Describes current charging state and remaining runtime State of Health: Provides information on the energy storage device life expectancy Input Voltage Output Description Order # 120 V AC/230 V AC 120 V AC/230 V AC - 1 kV A QUINT4-UPS/1 AC/1 AC/1 kV A 2320283 + Energy Storage What type of energy-storage device: VRLA, CAP, or LI-ION? How much current does the battery need to supply the system and for how long? See chart below. Energy-storage type VRLA UPS-BAT/PB W x H x D in mm 85 x 191 x 110 135 x 202 x 110 202 x 202 x 110 155 x 168 x 183 333 x 173 x 199 Capacity 4 Ah 7 Ah 12 Ah 20 Ah 40 Ah Type UPS-BAT/PB/ 24DC/4AH UPS-BAT/PB/ 24DC/7AH UPS-BAT/PB/ 24DC/12AH UPS-BAT/PB/ 24DC/20AH UPS-BAT/PB/ 24DC/40AH Order # 1274117 1274118 1274119 1348516 1354641 Buffer Time Performance Minutes Hours 2 3 4 5 8 10152025304050 1 1.52 3 4 6 9 10 100 W 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 200 W 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 300 W 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 400 W 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 500 W 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 600 W 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 700 W 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 800 W 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 900 W 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1: For the QUINT AC UPS/1KVA, two energy storage devices of the same capacity are always required. The data is based on an ambient temperature of +20°C. 1+1 QUINT4-UPS/1AC/1AC/1KVA and 2 x UPS-BAT/PB/24DC/12AH UPS-BAT/LI-ION UPS-BAT/VRLA-WTR W x H x D in mm 135 x 202 x 110 264 x 224 x 197 172 x 177 x 178 358 x 174 x 169 Capacity 128 Wh 924 Wh 13 Ah 26 Ah Type UPS-BAT/LI-ION/ 24DC/128WH UPS-BAT/LI-ION/ 24DC/924WH UPS-BAT/VRLA-WTR/ 24DC/13AH UPS-BAT/VRLA-WTR/ 24DC/26AH Order # 2320351 No Longer Available 2320416 2320429 Buffer Time Performance Minutes Hours 2 3 4 5 8 10152025304050 1 1.5 2 3 4 6 9 10 100 W 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 200 W 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 300 W 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 400 W 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 500 W 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 600 W 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 700 W 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 800 W 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 900 W 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1: For the QUINT AC UPS/1KVA, two energy storage devices of the same capacity are always required. The data is based on an ambient temperature of +20°C. 1+1 QUINT4-UPS/1AC/1AC/1KVA and 2 x UPS-BAT/LI-ION/24DC/924WH
RkJQdWJsaXNoZXIy MTI3ODI1