Phoenix Contact

PHOENIX CONTACT 13 Buffer times for your QUINT AC UPS/500VA with the following PB energy storage devices: Select your energy storage device for your QUINT AC UPS/500VA (120 / 230 V application) here. Example: 125 is to be buffered for one hour. Power Reliability For use with AC QUINT Power Supply Select UPS UPS Module What input voltage? What output power/current? QUINT UPS QUINT IQ Technology State of Charge: Describes current charging state and remaining runtime State of Health: Provides information on the energy-storage device life expectancy Input Voltage Output Description Order # 120 V AC/230 V AC 120 V AC/230 V AC - 400 W/500 V A QUINT4-UPS/1AC/1AC/500VA/USB 1067327 + What type of energy storage-device: VRLA, CAP, or LI-ION? Energy Storage How much current does the battery need to supply the system and for how long? See chart below. Energy-Storage Type VRLA Uninterruptible Power Supplies (UPS) AC Power - 500 VA Capacity - OFFLINE UPS UPS-BAT/PB W x H x D in mm 85 x 191 x 110 135 x 202 x 110 202 x 202 x 110 155 x 168 x 183 333 x 173 x 199 Capacity 4 Ah 7 Ah 12 Ah 20 Ah 40 Ah Type UPS-BAT/PB/24DC/4AH UPS-BAT/PB/24DC/7AH UPS-BAT/PB/24DC/12AH UPS-BAT/PB/24DC/20AH UPS-BAT/PB/24DC/40AH Order # 1274117 1274118 1274119 1348516 1354641 1+1: Two energy storage devices of the same capacity are required in this case. The data is based on an ambient temperature of +20°C. QUINT4-UPS/1AC/1AC/500VA/USB and UPS-BAT/VRLA/24DC/20AH Buffer Time Performance Seconds Minutes Hours 0.20.4 2 8 152040 1 2 3 5 102030404550 1 2 3 5 8 101520 15 W 1+1 35 W 1+1 55 W 1+1 90 W 1+1 125 W 1+11+1 180 W 1+1 275 W 1+11+1 400 W 1+1 UPS-BAT/LI-ION UPS-BAT/VRLA-WTR W x H x D in mm 135 x 202 x 110 264 x 224 x 197 172 x 177 x 178 358 x 174 x 169 Capacity 128 Wh 924 Wh 13 Ah 26 Ah Type UPS-BAT/LI-ION/24DC/128WH UPS-BAT/LI-ION/24DC/924WH UPS-BAT/VRLA-WTR/24DC/13AH UPS-BAT/VRLA-WTR/24DC/26AH Order # 2320351 No Longer Available 2320416 2320429 Buffer times for your QUINT AC UPS/500VA with the following energy storage devices: LI-ION, and VRLA-WTR Select your energy storage device for your QUINT AC UPS/ 500VA (120 / 230 V application) here. Example: 125 W is to be buffered for one hour. Buffer Time Performance Seconds Minutes Hours 0.20.4 2 8 152040 1 2 3 5 102030404550 1 2 3 5 8 101520 15 W 1+1 35 W 1+11+1 55 W 1+11+1 90 W 1+11+1 125 W 1+11+11+1 180 W 1+11+1 275 W 1+11+1 400 W 1+11+1 1+1: Two energy storage devices of the same capacity are required in this case. The data is based on an ambient temperature of +20°C. QUINT4-UPS/1AC/1AC/500VA/USB and UPS-BAT/VRLA-WTR/24DC/26AH +

RkJQdWJsaXNoZXIy MTI3ODI1